New York City is known for its iconic skyline, historic brownstones, and towering high-rises. While these structures give the city its charm, they also come with a critical responsibility: ensuring the safety of building facades. For NYC building owners, managers, and residents, Local Law 11 plays a crucial role in maintaining the integrity of exterior walls. Navigating this law effectively is essential to avoid penalties, protect property values, and, most importantly, safeguard public safety.

In this blog, we’ll break down everything you need to know about Local Law 11, explain the FISP inspection process, and provide practical guidance for compliance—without turning it into a bureaucratic headache.


Understanding Local Law 11

Local Law 11, also known as the Facade Inspection Safety Program (FISP), was introduced to ensure that buildings in New York City maintain safe exterior walls. The law specifically applies to buildings that are six stories or taller, mandating periodic inspections of their facades.

The primary goal of Local Law 11 is simple: to prevent accidents caused by falling masonry, loose bricks, or deteriorating building exteriors. Each cycle of inspection is part of a legal obligation, and non-compliance can result in hefty fines and legal complications.


Who Must Comply?

Local Law 11 applies to buildings in NYC that meet the following criteria:

  • Height of six stories or more

  • Commercial, residential, or mixed-use buildings

  • Buildings with facades made of brick, stone, terra cotta, or other masonry materials

Even if your building is relatively new, compliance is mandatory. While newer constructions may seem structurally sound, inspections still ensure that minor defects don’t develop into significant safety hazards over time.


What is FISP?

The Facade Inspection Safety Program (FISP) is the mechanism through which Local Law 11 is enforced. Every five years, buildings that fall under the law must undergo a thorough facade inspection, which is then documented in a FISP report submitted to the NYC Department of Buildings (DOB).


FISP Categories

After inspection, defects are classified into three categories:

  1. Class 1 – Immediate danger: Requires urgent repair. Non-compliance can result in immediate fines and even temporary closure of the building.

  2. Class 2 – Potential hazard: Repairs must be scheduled within a specific timeframe, usually 12 months.

  3. Class 3 – Maintenance issues: Less urgent, typically addressed during regular building maintenance.

These classifications help prioritize repairs and allocate resources efficiently. Failing to address Class 1 or Class 2 defects can lead to severe legal and financial consequences.


Step-by-Step Guide to Compliance

Navigating Local Law 11 doesn’t have to be overwhelming. Here’s a practical roadmap to stay compliant and avoid penalties:


1. Know Your Inspection Cycle

Local Law 11 operates on five-year cycles. Check your building’s DOB records to determine when your next inspection is due. Planning ensures that inspections are scheduled in advance of deadlines.


2. Hire a Qualified Professional

FISP inspections must be conducted by a licensed engineer or architect experienced in facade safety. Choosing a professional with experience in NYC is crucial because misfiled or incomplete reports can result in fines.


3. Conduct a Preliminary Survey

Before the official inspection, perform a preliminary assessment. This includes checking for:

  • Loose bricks or masonry

  • Deteriorating mortar joints

  • Water damage or stains

  • Cracks in stone or terra cotta

Addressing minor issues early can save time, money, and prevent severe violations.


4. Prepare the FISP Report

Once the inspection is complete, the engineer will submit a FISP report to the DOB. This report should include:

  • Photographs of defects

  • Defect classification (Class 1, 2, or 3)

  • Recommended repair timelines

Accurate reporting is crucial for demonstrating compliance and avoiding fines.


5. Implement Repairs Promptly

Prioritize Class 1 and 2 defects. Schedule repairs as soon as possible, ideally with licensed contractors familiar with NYC regulations. Maintaining records of all repair work is crucial in case of a DOB audit.


6. Maintain Ongoing Facade Safety

Even after the inspection, it’s wise to adopt a proactive maintenance plan:

  • Regularly check for water leaks

  • Inspect rooftop parapets and cornices

Consistent maintenance reduces the risk of sudden defects and keeps your building in good standing with Local Law 11.


Tips for Stress-Free Compliance

Here are some actionable tips to make Local Law 11 compliance smoother:

  1. Keep a Compliance Calendar – Track inspection cycles, deadlines, and repair schedules.

  2. Engage Experienced Professionals Early – Avoid last-minute inspections that may lead to rushed repairs.

  3. Document Everything – Keep copies of reports, permits, and repair invoices for at least five years.

  4. Budget for Repairs – Allocate funds annually to address potential facade issues.

  5. Educate Tenants and Staff – Ensure access for inspections and encourage reporting of visible defects.

By following these tips, building owners can not only comply with Local Law 11 but also enhance the longevity and safety of their buildings.


Final Thoughts

Navigating Local Law 11 in NYC may seem daunting, but with knowledge, preparation, and proactive maintenance, building owners can stay fully compliant without penalties. Understanding FISP requirements, scheduling inspections on time, addressing defects promptly, and keeping detailed records are the pillars of successful compliance.

Facade safety isn’t just a legal obligation—it’s a responsibility to everyone who lives, works, and walks around your building. By prioritizing inspections and repairs, NYC building owners not only adhere to Local Law 11 but also contribute to the city’s iconic skyline remaining safe and beautiful for generations to come.

 